The SINDIE-7039 Bench-Top analyzer is a compact, easy to use sulfur analyzer
designed for petroleum fuels from ultra-low sulfur diesel and gasoline to heavy
fuel oil. The SINDIE-7039 delivers unprecedented accuracy and precision,
and
provides the ultimate solution for the petroleum industry where
reliability and
speed are critical. Breakthrough Monochromatic
WD XRF technology
offers a limit of detection of 0.4 ppm
wt. with a dynamic range
up
to 3000 ppm wt. This
direct measurement technique
does not
require
sample conversion, consumable
gases or high
temperature operation.
The SINDIE-7039 design is
ideal for laboratory
and industrial use and requires
minimum
maintenance.
Total sulfur analysis from ULS fuels up
to 3000 ppm
From gasoline to heavy fuel oil
For pipeline terminals, refineries and
test laboratories
LOD: 0.4 ppm wt.
Dynamic range: 0.4-3000 ppm wt.
Repeatability:
| S Concentration | Std. Dev. |
| 1 ppm | 0.1 ppm |
| 10 ppm | 0.4 ppm |
| 100 ppm | 1.0 oom |
| 500 ppm | 1.7 ppm |
Fits on any bench in any lab:
14.5"(W) x 19.5"(D) x 13.5"(H)
Plug and go design: standard wall power is only utility required
User-friendly with touch screen interface
Flip-lid design for easy sample cup introduction
Measurment time 30s - 300s programmable
One calibration for diesel and gasoline matrixes over full dynamic range
Extremely low maintenance:
No conversion gases
No columns
No heating elements
No quartz tubing
Field replaceable air-cooled excitation tube
No sample conversion or combustible gases required
Polyamide x-ray windo, no exposed Be windows
Monochromatic excitation=Extremely low background No moving parts in analyzer engine No consumables or sample conversion required |
Linearity 0-500 ppm R2 = 0.9999 |
Successive sulfur measurements of diesel specimen at various sulfur concentrations on same analyzer. measurement time:300 seconds. ![]() |
Confidence Level. An interlaboratory study among six labs, using six different analyzers, analyzed 10 diesel fuels and 9 gasolines (some containing oxygenates). Samples were analyzed in duplicate and back-to-back. None of the labs used matrix correction calculation For information, contact your XOS representative. ![]() |
| Test Method: In accordance with ASTM Standard Test Method D-7039 Dimensions: 14.5"(W) x 19.58"(D) x 13.5"(H) Power: 100-120 VAC, 47-63 Hz at 6.0 Amps 200-240 VAC, 47-63 Hz at 6.0 Amps Other Utilities: None Sample Introduction: Maximum sample cup volume: 15cc I/O Ports: Ethernet 10/100 base T or RS232 |